The use of LAF factors is particularly important in multi-unit buildings where heating costs are settled individually based on heat cost allocator readings. Individual apartments do not have identical thermal conditions. Corner units, those on the top floor, or those located above an unheated basement may experience higher heat losses than apartments surrounded on all sides by heated rooms.
Equalization factors allow these differences to be taken into account when settling heating costs, ensuring a fairer distribution of charges among residents. These factors do not reduce the total heating costs of the building, but rather enable them to be more accurately allocated to individual units.
Legal basis
The obligation to include equalization factors arises from regulations governing the settlement of heat purchase costs in multi-unit buildings. The basis is provided by:
- The Energy Law Act of April 10, 1997, in particular Article 45a
- The Regulation of the Minister of Climate and Environment of December 7, 2021 (Journal of Laws 2021, item 2273), in particular §7(1)
The regulations indicate the necessity of including equalization factors resulting from the location of units within the building structure when choosing a method for settling heating costs. However, they do not impose one mandatory method for their calculation.
Nasze usługi w zakresie współczynników wyrównawczych LAF
Wyznaczymy dla Ciebie współczynniki wyrównawcze LAF, dzięki czemu możliwe będzie bardziej sprawiedliwe rozliczanie kosztów ogrzewania.
How do we determine LAF factors?
Determining LAF factors requires an individual thermal analysis of the building, carried out using specialized thermal calculation software. The process begins with an analysis of technical documentation, based on which the thermal parameters of partitions are determined and detailed calculations are performed for individual units. The results obtained allow for the identification of differences in heat demand resulting, among other things, from the location of apartments within the building's structure. On this basis, equalization factors are determined, taking into account the specifics of the particular facility.
Why is a heat balance the basis for a correct analysis?
LAF factors are sometimes adopted based on ready-made tables, such as those developed by COBRTI INSTAL. Such a solution is based on averaged assumptions and typical building layouts, without taking into account all the individual parameters of a specific facility. As a result, tabular values can differ significantly from the results of actual thermal calculations.
Therefore, the basis for a reliable analysis should be the building's heat balance, which allows for the determination of the design heat load and the heat demand of individual units. Thanks to this, the factors are determined based on the actual technical parameters of the facility, rather than just general assumptions regarding the apartment's location.
Appropriate methodology is particularly important because even units with a seemingly similar location may have different heat demands. Individual calculations make it possible to capture these differences and obtain results that are better suited to the characteristics of a specific building.