1. Analysis of the 15-minute load profile
The starting point for technical expertise should be an analysis of the actual annual energy consumption profile in 15-minute intervals. This data allows for precise mapping of the facility's energy needs in real time. Using profile analysis enables:
- Determining maximum instantaneous power demand: Essential for correctly sizing the installation and determining energy storage discharge parameters.
- Calculating self-consumption: Determining what portion of the energy produced from renewable sources will be consumed on-site and what will be sent to the grid or storage.
- Verifying contracted power: The ability to optimize distribution costs through peak shaving using a battery – the electrical energy storage system reacts to load spikes by discharging energy during periods of highest demand, which helps avoid exceeding the contracted power with the grid operator and thus prevents potential additional costs.
2. Building energy audit and energy efficiency audit
When designing renewable energy installations, two valuable diagnostic tools can be useful:
- Building energy audit - allows for the assessment of the facility's thermal modernization status, the demand for heating and cooling energy, and the identification of heat losses and critical areas requiring upgrades.
- Energy efficiency audit - focuses on technological processes, optimizing the operation of machinery, ventilation systems, compressed air, or lighting.
Their goal is, among other things, to identify potential methods for reducing energy consumption. Implementing the upgrades recommended in the audit can contribute to optimizing the energy consumption profile, and designing a photovoltaic installation in accordance with it ensures high investment profitability.
3. Process flexibility and Demand Side Response (DSR)
Before selecting an installation, it is worth analyzing technological processes for their flexibility. Some processes can be shifted in time to coincide with the production window (the time of day when renewable energy installations generate the most electricity) of a photovoltaic and/or wind installation. Implementing a Demand Side Response (DSR) strategy allows for:
- increasing the self-consumption of energy produced by the photovoltaic and/or wind installation
- reducing the demand for energy storage, and consequently decreasing the required energy storage capacity and associated capital expenditure (CAPEX).
Our renewable energy consulting and development services
We provide expert consulting for the planning, financing, and execution of renewable energy projects.
4. Selection of RES sources and energy storage parameters
Selecting PV system capacity
The capacity of a photovoltaic system for a business is selected with the goal of maximizing the self-consumption of energy generated for its own needs.
Selecting an energy storage system
For energy storage systems, it is crucial to determine not only the capacity (kWh or MWh) but also the charge and discharge power (kW or MW). These parameters should be based on an analysis of the 15-minute energy consumption profile and the specific objective the storage system is intended to achieve.
If the storage system is primarily intended for peak shaving, its power rating will be the most important parameter. If the goal is to increase the utilization of energy from a PV system or for price arbitrage, the storage capacity becomes more significant. In practice, the optimal selection of a storage system requires an analysis of energy production surpluses, load characteristics, and both current and projected electricity costs.
Other RES sources - wind energy
For businesses with suitable site conditions, it is also worth considering the use of wind energy. Unlike photovoltaic installations, wind turbines often achieve higher productivity during the autumn and winter months and at night, making them a natural complement to PV systems.
Before making an investment decision, it is necessary to analyze the local wind potential, land availability, environmental constraints, and grid connection conditions. In some cases, combining a photovoltaic installation, a wind source, and an energy storage system allows for a higher level of self-consumption and greater stability in energy costs than using only a single RES source.
Summary
An engineering approach to RES requires strictly following a sequence of actions: from measuring consumption and reducing needs, to selecting generation sources. Skipping the 15-minute analysis or audit stage is a direct path to under- or oversizing the installation, both of which reduce the profitability of the entire project.